Elisa Microplate Reader STATFAX 2100, MADE IN USA-AMERICA

Stat Fax 2100 Microplate Reader

Features:
  • Fully automatic. 
  • Bichromatic optics 
  • On board data reduction calculations include regressions, curve fitting, and cutoff absorbance calculations with step-by-step user prompting. 
  • Includes parallel and serial outputs. 
  • Large, non-volatile memory stores at least 50 user entered tests.


  Photometric
  Linear Measurement Range:      - 0.20 to 3.0 Absorbance Units (A)
  Photometric Accuracy:          1% or better
  Stability:                     Drift of no more than 0.005A in 8 hours
  Light Source:                  Tungsten lamp, with lamp saver feature
  Wavelengths:                   Standard - 405, 450, 492, and 630nm
                                 6-VIS - 405, 450, 492, 545, 600, and 630nm
                                 6-UV - 340, 405, 450, 492, 545, and 630nm
  Type of Filter:                Multiple-cavity hard coat interference, 10nm half bandpass
  Vessel:                        Standard 96-well microtiter plates or strip trays
  

  Electronics
  Display:                       Two-line LCD, alphanumeric, 24 characters per line
  Printer Requirements:          Parallel or serial, 80 column, 2K byte minimum
                                 buffer capacity, EPSON compatible
  Keyboard:                      29-key, domed membrane switch, enunciating
  Power Requirements:            115V/230V, 50/60Hz (switch selectable)
  Serial Port:                   2400 baud, 1 start bit, 8 data, 1 stop, no parity
  Microprocessor:                Z80A or Z180
  Non-Volatile Memory:           Battery supported RAM, holds approx. 50 tests and curves
  

  Software
  Speed:                         Reads and prints absorbances of 96 wells in about 2 minutes
  Calculation Modes:             Single-point calibration, uptake mode, point to point
                                 curve fit, polynomial regression, linear regression (log 
                                 & linear), cutoff absorbance, multipoint % absorbance
  Additional Features:           Complete user prompting, flags and error messages, 
                                 partial plate reading, alphanumeric test naming, auto-
                                 matic interpretation options, duplicate options, clock
                                 and calendar, controls locator, self-check system, curve 
                                 plotting and editing
  

  Other
  Mixer:                         Variable time, fixed speed
  Enclosure:                     Fire-retardant ABS plastic cover with metal base
  Dimensions:                    17 x 14.5 x 7
  Weight:                        30lbs.
  Certifications:                UL Listed, CE Mark available


Elisa Microplate Washer STATFAX 2600, MADE IN USA-AMERICA

                                    Stat Fax 2100 Microplate Washer


Stat Fax® 2600
• Fully automatic.
• Washes flat, round, and V-bottom plates and strips.
• No user adjustments required. Automatic calibration, alignment, and last row detection.
• 6 ready-to-run wash progams.
• Large, non-volatile memory stores at least 50 user-specified wash protocols.
• Precision operation with constant monitoring of vacuum and pressure. Pump cycles only when necessary for quiet operation.
• Programmable automatic rinse cycle.
• Ready to run: bottles, aerosol shield, 8-way manifold included.
• 12 and 16 position wash heads available.
• NRTL and CE certified.


Stat Fax®2600
Residual Volume<3ul
Processing Time
(Full Plate)
55 seconds aspirate/dispense
(8 Probe Wash Head Standard (12 or 16 Probe Wash Heads Available)
Dispense Accuracy< 3% CV at 300 ul
Liquid Contact MaterialsStainless steel, Delrin, silicone, nylon, PVC, polypropylene
DisplayTwo-line LCD, alphanumeric, 24 characters per line
Washing ProgramsAspirate, dispense, soak - up to 99 minutes 99 seconds
Non-Volatile MemoryBattery supported RAM, holds approx. 50 wash protocols
Keyboard16-key, domed membrane switch, 4 x 4, enunciating
MicroproccssorZ80A or Z180
Power Requirements115V, 50-60Hz (switch selectable)
BottlesPlastic, Wash and Waste (2L), Rinse (1L)
EnclosureFire-retardant ABS plastic cover with metal base
Dimensions39 x 34 x 19 cm, 8.6 kg
CertificationsNRTL Listed、CE Mark
Special Menu OptionsAuto Alignment - senses physical geometry of the head, plate, and carrier mechanism
Standby-disables pumps and releases vacuum and pressure
Self-Check-performs internal performance tests alignment
Auxiliary-allows selection of pre-programmed tests, mechanism                                                             
and volume calibration, and alphanumeric test naming
Constant Plate Cycle Time
Optional Manual Plate Depth Selection
CertificationsNRTL Listed, CE Mark

Harga: harga 1 set lengkap Elisa (reader-washer) 150 juta, bonus stabilizer, UPS ICA, Printer EPSON dotmatrik, reagent trial. Garansi 1 tahun...


  

5 komentar:

  1. Komentar ini telah dihapus oleh pengarang.

    BalasHapus
  2. Alat untuk cek immunology (Hepatitis, HIV AIDS, Herpes, Hormon, Kanker, sypilis, influenza) dan lain2... masih NEGGO!!!

    BalasHapus
  3. Komentar ini telah dihapus oleh pengarang.

    BalasHapus
  4. Alat ASLI buatan AMERICA, hasil dijamin absah, Alat bandel, tahan lama masa pakai bisa sampai 10-15 tahun keawetannya, sparepart ready stock....
    bagus buat investasi jangka panjang pemilik usaha di bidang RS, atau laboratorium klinik , medical center dll.

    BalasHapus

JUAL HEMATOLOGY 5 DIFF TANPA BARCODE BERGARANSI 2024

 JUAL HEMATOLOGY 5 DIFF TANPA BARCODE BERGARANSI 2024   JUAL HEMATOLOGY 5 DIFF TANPA BARCODE OPEN SYSTEM PT. ABHISEVA VICTORIE AZZURA Melaya...