JUAL ALAT ELISA MERK: STATFAX Made in: USA AMERICA


JUAL ELISA READER WASHER MERK: STATFAX Awareness Technology,, Made in: USA

JUAL ELISA STATFAX 2100 & WASHER 2600
JUAL READER-WASHER STATFAX MURAH
JUAL READER WASHER BUATAN AMERICA
JUAL READER WASHER BAGUS AWET
JUAL ALAT IMMUNOLOGY READER WASHER



Elisa Microplate Reader STATFAX 2100, MADE IN USA-AMERICA

Stat Fax 2100 Microplate Reader

Features:
  • Fully automatic. 
  • Bichromatic optics 
  • On board data reduction calculations include regressions, curve fitting, and cutoff absorbance calculations with step-by-step user prompting. 
  • Includes parallel and serial outputs. 
  • Large, non-volatile memory stores at least 50 user entered tests.


  Photometric
  Linear Measurement Range:      - 0.20 to 3.0 Absorbance Units (A)
  Photometric Accuracy:          1% or better
  Stability:                     Drift of no more than 0.005A in 8 hours
  Light Source:                  Tungsten lamp, with lamp saver feature
  Wavelengths:                   Standard - 405, 450, 492, and 630nm
                                 6-VIS - 405, 450, 492, 545, 600, and 630nm
                                 6-UV - 340, 405, 450, 492, 545, and 630nm
  Type of Filter:                Multiple-cavity hard coat interference, 10nm half bandpass
  Vessel:                        Standard 96-well microtiter plates or strip trays
  

  Electronics
  Display:                       Two-line LCD, alphanumeric, 24 characters per line
  Printer Requirements:          Parallel or serial, 80 column, 2K byte minimum
                                 buffer capacity, EPSON compatible
  Keyboard:                      29-key, domed membrane switch, enunciating
  Power Requirements:            115V/230V, 50/60Hz (switch selectable)
  Serial Port:                   2400 baud, 1 start bit, 8 data, 1 stop, no parity
  Microprocessor:                Z80A or Z180
  Non-Volatile Memory:           Battery supported RAM, holds approx. 50 tests and curves
  

  Software
  Speed:                         Reads and prints absorbances of 96 wells in about 2 minutes
  Calculation Modes:             Single-point calibration, uptake mode, point to point
                                 curve fit, polynomial regression, linear regression (log 
                                 & linear), cutoff absorbance, multipoint % absorbance
  Additional Features:           Complete user prompting, flags and error messages, 
                                 partial plate reading, alphanumeric test naming, auto-
                                 matic interpretation options, duplicate options, clock
                                 and calendar, controls locator, self-check system, curve 
                                 plotting and editing
  

  Other
  Mixer:                         Variable time, fixed speed
  Enclosure:                     Fire-retardant ABS plastic cover with metal base
  Dimensions:                    17 x 14.5 x 7
  Weight:                        30lbs.
  Certifications:                UL Listed, CE Mark available


Elisa Microplate Washer STATFAX 2600, MADE IN USA-AMERICA

                                    Stat Fax 2100 Microplate Washer


Stat Fax® 2600
• Fully automatic.
• Washes flat, round, and V-bottom plates and strips.
• No user adjustments required. Automatic calibration, alignment, and last row detection.
• 6 ready-to-run wash progams.
• Large, non-volatile memory stores at least 50 user-specified wash protocols.
• Precision operation with constant monitoring of vacuum and pressure. Pump cycles only when necessary for quiet operation.
• Programmable automatic rinse cycle.
• Ready to run: bottles, aerosol shield, 8-way manifold included.
• 12 and 16 position wash heads available.
• NRTL and CE certified.


Stat Fax®2600
Residual Volume<3ul
Processing Time
(Full Plate)
55 seconds aspirate/dispense
(8 Probe Wash Head Standard (12 or 16 Probe Wash Heads Available)
Dispense Accuracy< 3% CV at 300 ul
Liquid Contact MaterialsStainless steel, Delrin, silicone, nylon, PVC, polypropylene
DisplayTwo-line LCD, alphanumeric, 24 characters per line
Washing ProgramsAspirate, dispense, soak - up to 99 minutes 99 seconds
Non-Volatile MemoryBattery supported RAM, holds approx. 50 wash protocols
Keyboard16-key, domed membrane switch, 4 x 4, enunciating
MicroproccssorZ80A or Z180
Power Requirements115V, 50-60Hz (switch selectable)
BottlesPlastic, Wash and Waste (2L), Rinse (1L)
EnclosureFire-retardant ABS plastic cover with metal base
Dimensions39 x 34 x 19 cm, 8.6 kg
CertificationsNRTL Listed、CE Mark
Special Menu OptionsAuto Alignment - senses physical geometry of the head, plate, and carrier mechanism
Standby-disables pumps and releases vacuum and pressure
Self-Check-performs internal performance tests alignment
Auxiliary-allows selection of pre-programmed tests, mechanism                                                            
and volume calibration, and alphanumeric test naming
Constant Plate Cycle Time
Optional Manual Plate Depth Selection
CertificationsNRTL Listed, CE Mark

Harga: harga 1 set lengkap Elisa (reader-washer) 150 juta, bonus stabilizer, UPS ICA, Printer EPSON dotmatrik, reagent trial. Garansi 1 tahun...